Manual Override

If you lose power or experience motor failure, the awning can be extended and retracted manually. This override can also be used if you’re dry camping or camping without a battery.

  1. Remove the rubber grommet form the drive head assembly, this will expose the override nut on the motor.
    alliance RV paradigm 2021 Manual Override User Manual 01
  2. Using a 7/16” socket and a drill, turn the override nut counterclockwise to retract the awning.
    alliance RV paradigm 2021 Manual Override User Manual 02
  3. When the awning is completely retracted, remove the drill and replace the rubber grommet.

 Awning Component Breakdownalliance RV paradigm 2021 Manual Override User Manual 03

Slideout Toppers

Alliance RV has prepped their fifth wheels with a slide topper prep kit to allow for easy installation of a Solera Slideout Topper at a later date. For assistance with parts and or questions regarding the slideout topper prep kits, please contact your Alliance Dealer or Alliance RV.

  • The top left and right hand corners, just beneath the slideout fascia, you’ll find the bracket (shown below) installed.

alliance RV paradigm 2021 Manual Override User Manual 04

alliance RV paradigm 2021 Top Accessories

[amalinkspro_table id=”32452″ new-window=”on” nofollow=”on” addtocart=”off” /]

HEATING, COOLING & VENTILATION

Air Conditioning
Alliance RV main living quarters (downstairs) will utilize two “direct cool” Coleman air conditioners. These units are mounted on the exterior roof of the RV with a combination shroud mounted on the inside ceiling of the RV. We’ve opted for most of the RV to be cooled with these direct cool units as they are significantly more efficient than your typical ducted system. The front/upper deck of the RV will utilize a ducted Coleman air conditioner system. Due to the nature of the design in the front/upper deck containing multiple rooms and areas that can be isolated with doors, a ducted system is utilized.
Each air conditioner will be operated by its own individual thermostat.

alliance RV paradigm 2021 Manual Override User Manual 05

Furnace
Every Alliance RV will be heated with an SF‐Q series Suburban furnace that provides 42,000 BTU’s. An exterior access door allows for ease of service. The furnace is operated with the Airxcel thermostat that is tied to the main air conditioner unit. The main air conditioner unit is the control that operates the central air conditioner in the RV.

HEATING, COOLING & VENTILATION (CONTINUED)

Operating the Furnace

WARNING
DO NOT OPERATE THE FURNACE WHILE THE VEHICLE IS IN MOTION OR BEING TOWED

NOTE:
During the initial firing of this furnace, a burn‐off of excess paint and oils remaining from the manufacturing process may cause “smoking” for 5 – 10 minutes.

  1. Stop! Read the furnace user’s manual supplied with the furnace.
  2. Turn the manual valve (if equipped) or the valve at the outside propane tank to the “OFF” position. Do not force
  3. Set the thermostat above room temperature to begin the blower operation. A slight delay will occur before the blower comes on. Allow the blower to run for 5 minutes for the combustion chamber purge cycle. If the blower does not come on or stops before the ignition cycle, go to shut it down and contact your dealer.
  4. After 5 minutes, move the thermostat lever below room temperature. The blower will remain on. Wait approximately 2 minutes for the blower to go off.
  5. Open the manual shut‐off valve (if equipped) or the valve at the outside propane tank. Correct operating characteristics depend on the valve being positioned fully open. Never attempt to operate with a valve partially closed. NOTE: This furnace is equipped with a valve shut‐off switch. If the furnace is started with shut‐off switch in “OFF” position, the furnace motor will run for 30 seconds, then shut off. During this sequence, no gas will flow to the burner and the furnace will lock out requiring the user to cycle either the thermostat or unit power to reset the furnace. Ensure the shut‐off switch is in the “ON” position for proper operation.
  6. Set the thermostat to the desired setting. If set above room temperature, the blower will come on.
  7. Allow 30 seconds for main burner to light after blower comes on. This furnace is equipped with an ignition device which automatically lights the burner. Do Not try to light the burner by hand.
  8. If the burner does not light, repeat steps 1 thru 8.
  9. If after three 3 attempts with no ignition, go to shut down and contact your dealer. Do not continue to cycle the furnace.

NOTE: If the furnace locks out, the blower will go off in 5 minutes and remain off until it is reset by reactivating the thermostat.

Operating the Furnace (Continued)

To Turn the Furnace Off

  1. Set the thermostat to lowest setting, then turn the thermostat to the “OFF” position.
  2. Turn the manual shut off valve (if equipped) to the “OFF” position.

Thermostat
The display indicates the mode and the room temperature. When the mode button is pressed once, the thermostat will wake. When the mode button is pressed again, the mode will change. Press the up or down button to wake the thermostat, the set temperature will display, and the mode will flash. Press the up or down button again to change the set temperature. The thermostat will go back to sleep after 5 seconds of no activity.alliance RV paradigm 2021 Manual Override User Manual 07

There is a three‐minute anti‐short cycle for cooling. After the cooling system has been de‐energized, the system will not energize again for three minutes, this is to protect the compressor on the ac unit. You can bypass the anti‐short cycle function by changing the mode to off.

NOTE: Operating your cooling system when the outdoor temp is below 50 deg Fahrenheit can cause damage to your cooling equipment.

NOTE: Hold the mode button down for 5 seconds to change from Fahrenheit to Celsius.

Fireplace

Your RV is equipped with an electric fireplace with a BTU rating of 5100. You’ll be able to use this to help knock the chill off on cold days, this fireplace is not intended to heat your entire RV nor will it do so. You can operate the fireplace at the control panel on the fireplace itself or wit the remote.

Control Panel alliance RV paradigm 2021 Manual Override User Manual 06

  • Power button – Press this button to turn the fireplace on. The unit will beep. Press again to turn the fireplace off.
    NOTE: The fan will continue to run for 60 seconds without heat.
  • Flame Color – Press this button to change the flame color. The unit will beep – press once for orange, press twice for an orange’s blue, press three times for blue.
  • Flame Effect – Press this button to change the flame effect. The unit will beep. Press again to decrease the flame intensity. There are 6 light settings for your selection. The flame optics will go lower under the sequence of 6,5,4,3,2,1. Pressing the button again will stop the flame effect.
  • Temperature – Press this button to set the temperature. The unit will beep. Press to set the desired temperature. When desired ambient temp is reached, the heater will automatically stop heating. When the ambient temperature drops below the set point, the heater will resume heating.